Organisational Factors » LTA hazard analysis/job safety analysis

Resource List

Please select a resource below to see more detail.


Information

Link:

Click here to view file.

Mine Type:

Any Mine Type

Published:

May 25, 2007

Incorrect Isolation Of Conveyor

At the end of a job on a conveyor it was discovered that the local control isolator had been locked in the "ON" position during the ...

Click to see full details...


Information

Link:

Click here to view file.

Mine Type:

Underground Coal Mine

Published:

May 22, 2008

Mine Worker Suffers Chemical Burns to Eyes due to High Pressure Fluid Release

A coal mine worker received facial injuries and chemical burns to his eyes as a result of the uncontrolled release of diluted foam catalyst ...

Click to see full details...


Information

Link:

Click here to view file.

Mine Type:

Any Mine Type

Published:

Nov 28, 2008

Fatal Crush Injury on Exploration Site

A water truck operator sustained fatal injuries when he was crushed between the rear of his water truck and a pastoral property gate. The ...

Click to see full details...


Information

Link:

Click here to view file.

Mine Type:

Any Mine Type

Published:

Dec 1, 2008

Contamination of Fresh / Potable Water Supply

An incident occurred recently where the fresh / potable water system in a processing plant was connected to the final product line. At some ...

Click to see full details...


Information

Link:

Click here to view file.

Mine Type:

Surface Mine

Published:

Dec 24, 2008

Fatality Involving Mobile Crushing Plant

A worker sustained fatal injuries when struck by the right hand hopper door of a mobile crushing plant.

Click to see full details...


Information

Link:

Click here to view file.

Mine Type:

Any Mine Type

Published:

Mar 10, 2008

Shock from an Electrostatic Discharge

In certain circumstances electrostatic charges can build up on materials that when touched by a person can cause immediate pain and a potential ...

Click to see full details...


Information

Link:

Click here to view file.

Mine Type:

Any Mine Type

Published:

Jan 20, 2000

Failure To Isolate Compressed Air Line

In an Underground coal mine two parallel pipe branches comprising a 100mm compressed air line and a 100 mm pump line had been installed. The ...

Click to see full details...


Information

Link:

Click here to view file.

Mine Type:

Any Mine Type

Published:

Jan 14, 2000

Coal Reclaim Tunnel Incident

The coal reclaim system comprised a stockpile located over a hopper which fed coal onto a conveyor in reclaim tunnel below via a clam shell ...

Click to see full details...


Information

Link:

Click here to view file.

Mine Type:

Any Mine Type

Published:

Jan 28, 2000

Toe Amputation by Drill String

Toe amputation by drill string.

Click to see full details...


Information

Link:

Click here to view file.

Mine Type:

Any Mine Type

Published:

Feb 24, 2002

Contractor Struck By Bull Gear Cover

Two dragline bullgear covers were removed during a maintenance shut down and placed on a dry level area for cleaning. They were placed in an ...

Click to see full details...


Information

Link:

Click here to view file.

Mine Type:

Underground Coal Mine

Published:

Apr 22, 2002

Exposed Live 11Kv Cable Plug

At an underground coal mine, an electrician and work group were required to energize a newly installed 11KV underground substation. This was to ...

Click to see full details...


Information

Link:

Click here to view file.

Mine Type:

Surface Mine

Published:

Oct 24, 2002

Trip Switch Defeated On Pug Mill Chamber

Recent inspections at four separate quarries identified that safety devices (trip switches) intended to stop pug mill augers rotating when the ...

Click to see full details...


Information

Link:

Click here to view file.

Mine Type:

Surface Mine

Published:

Mar 4, 2003

Inappropriate Safety Props

While undertaking an inspection at a quarry, a dump truck was found parked up with the tray in the raised position to allow maintenance to be ...

Click to see full details...


Information

Link:

Click here to view file.

Mine Type:

Underground Coal Mine

Published:

Aug 27, 1999

Accidents on Continuous Miners during Maintenance Work Underground

Since 1996 in the underground coal industry, there have been two fatal accidents and one very serious accident (double amputation) all ...

Click to see full details...


Information

Link:

Click here to view file.

Mine Type:

Any Mine Type

Published:

Feb 11, 2000

Uncontrolled Movement of Vehicles

Several recent high potential incidents involving mine/quarry vehicles have prompted the issue of this Safety Bulletin. Brief details of some ...

Click to see full details...


Information

Link:

Click here to view file.

Mine Type:

Any Mine Type

Published:

Apr 19, 2000

Use of Restraining Devices on Hoses

This is a reminder that any hose containing any liquid or gas under pressure has the potential to cause injury if the pressure is released in ...

Click to see full details...


Information

Link:

Click here to view file.

Mine Type:

Any Mine Type

Published:

Apr 30, 2004

Tyre Fires, Pyrolysis And Explosions

Tyres on trucks, cranes and other heavy vehicles may catch fire under a range of circumstances, with the obvious potential for the tyres to ...

Click to see full details...


Information

Link:

Click here to view file.

Mine Type:

Surface Mine

Published:

Oct 31, 1997

Near Miss Electrocution

A contract fitter engaged in the repair of a dragline lower roller path entered the tub 22KV cable connection chamber with the power still ...

Click to see full details...


Information

Link:

Click here to view file.

Mine Type:

Any Mine Type

Published:

Jun 23, 1997

Service Pipe Ranges

A number of recent incidents in mines have prompted the inspectorate to issue this bulletin regarding the potential for serious injury to arise ...

Click to see full details...


Information

Link:

Click here to view file.

Mine Type:

Any Mine Type

Published:

Jul 1, 1991

Crane Dogman Survives Shock From 22kV Transformer

During the dismantling of a monorail structure, a 15 metre section of beam supported by a mobile crane contacted the High Voltage terminals of ...

Click to see full details...


Information

Link:

Click here to view file.

Mine Type:

Surface Mine

Published:

Aug 1, 1991

Buried Electric Cable – Fatal Accident

While excavating to repair a leaking water main, a trades assistant was electrocuted when a crowbar he was using struck and penetrated a buried ...

Click to see full details...


Information

Link:

Click here to view file.

Mine Type:

Any Mine Type

Published:

May 27, 1997

Conveyor Belt Failure

A conveyor belt broke on an inclined conveyor carrying ore from the crusher to a stockpile. Eight employees after placing their danger tags on ...

Click to see full details...


Information

Link:

Click here to view file.

Mine Type:

Surface Coal Mine

Published:

Nov 1, 2006

Large Electrical Equipment At Surface Mines May Have Auxilliary Power Sources

COAL MINE FATALITY – An electrician, with 21 years of experience, was fatally injured while troubleshooting a dragline trailing cable at ...

Click to see full details...


Information

Link:

Click here to view file.

Mine Type:

Any Mine Type

Published:

Jun 27, 2005

Electric Shock From 11 kV Bus Tie

INCIDENT

A contract electrician received a serious electric shock and burns when live 11 kV bushings in the rear of a bus tie ...

Click to see full details...


Information

Link:

Click here to view file.

Mine Type:

Any Mine Type

Published:

Jan 15, 2002

Alternate Radio Transmitter Signals Start Machine

INCIDENT

A remote controlled machine was being tested in a surface workshop using radio remote control. The hydraulic pump on the ...

Click to see full details...